ROLE OF THE CONTROL MODULE

• Monitor and control the operation of the fire extinguishing system

• Receive and process alarm signals from the place where a fire occurs (input)

• Send fire alarm signals to sirens / fire alarm lights / close or open connected control relays (output).

• Send the activation signal to the fire extinguishing gas cylinder to discharge aerosol extinguishing gas.

• Send the notification signal that the aerosol fire extinguishing system has been activated

FEATURES OF THE AEROSOL FIRE EXTINGUISHING SYSTEM CONTROL MODULE

FEATURES OF THE AEROSOL FIRE EXTINGUISHING SYSTEM CONTROL MODULE

DSPA µ-FEP control module

• Can set alarm/ fire extinguishing by manual, single zone or double zone.

• Outputs used for fire alarm devices, fault alarm, fire extinguishing discharge activation, ventilation shutdown signal, alarm by light, by bell/horn.

• 1 supervised output used for aerosol fire extinguishers.

• 2 supervised fire alarm input zones used for heat detectors and/or smoke detectors.

• 2 supervised input groups used for the gas discharge activation switch (release button) and the gas discharge activation stop switch (abort button).

• Gas discharge delay button to prevent unwanted gas discharge.

• Has test mode, allowing testing of fire detectors, signal testing, control part testing without discharging gas.

• Supervises faults and indicates faults.

• Supervises faults of the fire extinguishing gas discharge output.

• Supervises faults of the fire detector input.

• Allows selecting to bypass the gas discharge delay time after pressing the manual gas discharge button.

• Has an event history recording memory, can be read through the USB port.

• Has RS485 communication port.

* Input voltage: 6 ~ 28 Volt DC

TECHNICAL CHARACTERISTICS OF FEM-01 MODULE

TECHNICAL CHARACTERISTICS OF FEM-01 MODULE

FEM-01 control module

Power supply 100 ~ 220 VAC

Battery capacity 2 x 7.5 Ah

Connection wire 2 wires - diameter 2.5 mm2

Number of connected zones 2 zone

Number of fire detectors per zone 32 detectors

Alarm output Relay (C, NC, NO)

Humidity . 95% non-condensing

Operating temperature -5oC ~ +40oC

Weight 2 kg

Dimensions 250 x 250 x 50 mm

Cabinet enclosure material Steel